News from TT-Magazine

Banner
Products PDF Print E-mail
For more informations see our catalogues

Our current product range includes:


micro_cables_fiber_optic

TRATOS MICROCABLES

MICRODUCT

144 fibre
Central dielectric support FRP
Jelly filled loose tubes
(24 FO - 200 um)
HD PE outer sheath

192 fibre
Central dielectric support FRP
Jelly filled loose tubes
(24 FO - 200 um)
HD PE outer sheath

 CABLE PERFORMANCES

TEST NORMS of REFERENCE NOMINAL VALUE
Minimum bending radius IEC 60794-1-2 - E11 under max. tension 20 x outer diameter
without tension 15 x outer diameter
Tensile test IEC 60794-1-2 - E1 installation (temporany) 144:500 N 192: 1000 N
operative (permanent)
144: 200 N 192: 400 N
Impact test IEC 60794-1-2 - E4 Energy: 3 J
N° impact: 3
Max. att. increase
Max. att. increase
Crush test IEC 60794-1-2 - E3 1000 N/10 cm Max. att. increase
<0,05 dB (reversible)
Temperature cycling IEC 60794-1-2- F1 operating -30°C / +60oC
transport & Storage -40°C / + 70°C
installation -15°C / +60oC
Water penetration IEC 60794-1-2- F5 3 m cable; 1 m water
column x 24 h
no leakage

micro_tubes_fiber_optical

TRATOS MICROCABLE

MICRODUCT AEREO

Central dielectric support FRP
PE
Strength members aramid yearns
Tube
HD PE

 

 

CABLE PERFORMANCES

TEST NORMS of REFERENCE NOMINAL VALUE
Minimum bending radius IEC 60794-1-2 - E11 ≤40 x  outer diameter
Tensile test IEC 60794-1-2 - E1 Max. installation tension
5000 N
operative (permanent)
144: 200 N 192: 400 N
Impact test IEC 60794-1-2 - E4 Energy: 15 J
N° impact: 3
Max. att. increase
<0,05 dB (reversible)

Temperature cycling

EC 60794-1-2- F1

transport & Storage -40°C / + 70°C
Installation -20°C / +50°C

Water penetration

IEC 60794-1-2- F5

3 m cable; 1 m water
column x 24 h
no leakage